General Configurable Synchronisation ErrorsGeneral Configurable Synchronisation Errors

What

There are a several synchronisations in Pure build on the same framework. We call the Configurable synchronisations.
Because they are build like this, several job logs you see will be similar and have the same root cause.
This article gives some examples and explains how to troubleshoot various errors that might be encountered with the configurable synchronisations e.g. Organisation, Person and User.

How

In Administrator > Jobs > Cron job scheduling or Job log, you can find the specific job and the logs for the latest runs.

Safe size

Job log
Checking safe size
FATAL: Safe size not met! Safe size is 1 but only 0 IDs returned.
  • The safe size is a safeguard to prevent Pure from removing your synchronised content.
  • Synchronisation safe size (under Job configuration > Synchronisation configurations): The synchronisation source must have at least this many records to be valid. If there is less the synchronisation job will not run.
  • The safe size will only be enforced if Pure contains an amount of synchronized content above the safe size configured (e.g. if Pure has 98 organisations and the safe size is 100, then the job ignores the setting for safe size).
    • If you get the error because you intentionally have less in your source, then you should update this to avoid the error.
    • If the amount is not intentionally smaller, then the issue might be because:
      • The source is missing some data.
      • The source is not available to Pure (this could be due to security settings or wrong paths). Confirm the Job configuration > Dataprovider configurations:

        • As an example if the safe size (like the example above) is 1 and not met. In this case the job log should provide more relevant details it could be :
ERROR: Error reading from [_https://share.atira.dk/xx/xxx/hostedProd/12092019/organisations12-09-2019_11_23__]

Invalid email

Job log
Closing external information provider
FATAL: Job terminated with uncaught exception
----------------- Validation error -----------------
Recipient: 0 is not a valid email
Exception details
Validation of content 'EmailQueueEntry(id=<null>, emailInformation=EmailInformation(replyTo=<null>, replyToName=<null>, recipient=0, recipientName=<null>, subject=PURE FATAL: synchronisation job: organisationUnifiedSynchronisation))' failed:
Validation errors:
emailInformation.recipient: ValidationResult [code=validation.text.email, args=null, nestedProperty=null, value=0], propertyPath: emailInformation.recipient
  • This is caused by having an invalid email in the job configuration of the synchronisation. In this example, there is a"0" in a field where an email should go:

    • The email is used when the job encounters a fatal error it then looks for an email, but in this case threw back another error because the email in this field was invalid.
  • Correct the email under Job configuration > Synchronisation configurations to avoid this error.

More information

Configurable rules for data synchronisation 
Transitioning to the Configurable synchronisation 
Disable the calculate for data changes in Configurable Synchronisations 
Global Sync/Import Configurations 
Configurable job setting: Legacy synchronisation sources 
Duplicate data in Configurable User Synchronisation

Note: Some of this information is for internal use only and might not be accessible.

Published at January 15, 2024

Download
Table of Contents
  1. What
  2. How
Related Articles
  • Synchronisation and employment terminations
  • Check Which WoS Edition Outputs are Imported From
  • Web Service: 524 Endpoint Becomes Persistent
  • ORCID Mapping of subtypes
  • Export to SciVal
Keywords
  • config
  • synchronization
  • sync
  • fatal
  • validation
  • organization
  • valid
  • mail
  • 5.18.0
  • 5.17.0
  • 5.19.0
  • 5.20.0

Was this article helpful?

Yes
No
Give feedback about this article

    About Pure

  • Announcements

    Additional Support

  • Events
  • Client Community
  • Training

    Need Help?

  • Contact Us
  • Submit a Support Case
  • My Cases
  • Linkedin
  • Twitter
  • Facebook
  • Youtube
Elsevier logo Relx logo

Copyright © 2025 Elsevier, except certain content provided by third parties.

  • Terms & Conditions Terms & Conditions
  • Privacy policyPrivacy policy
  • AccesibilityAccesibility
  • Cookie SettingsCookie Settings
  • Log in to Pure Help CenterLog in to Helpjuice Center

Knowledge Base Software powered by Helpjuice

Expand